User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-147882143References: M-ALPS04356754 This could lead to local escalation of privilege with no additional execution privileges needed. In the ioctl handlers of the Mediatek Command Queue driver, there is a possible out of bounds write due to insufficient input sanitization and missing SELinux restrictions. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-145988638References: Upstream kernel In binder_transaction of binder.c, there is a possible out of bounds write due to an incorrect bounds check. User interaction is not needed for exploitation.Product: AndroidVersions: Android-8.0 Android-8.1 Android-9 Android-10Android ID: A-143894715 This could lead to remote code execution over Bluetooth with no additional execution privileges needed. In reassemble_and_dispatch of packet_, there is possible out of bounds write due to an incorrect bounds calculation. User action is needed for exploitation.Product: AndroidVersions: Android-8.0 Android-8.1 Android-9 Android-10Android ID: A-128674520 This could lead to a local escalation of privilege with no additional execution privileges needed. It is possible for a malicious application to construct a TYPE_TOAST window manually and make that window clickable. Product: Android Versions: Android-8.0, Android-8.1, Android-9, and Android-10 Android ID: A-140055304 User interaction is not needed for exploitation. Nice to know how to view the running processes for instances like this or resolving other issues.In getProcessRecordLocked of ActivityManagerService.java isolated apps are not handled correctly. # diag sys kill 11 – Using the process ID from above you can restart a process using this command.Īfter running these commands, the GUI was then accessible again. In our case it was the two “httpsd” processes. # get sys perf top – This will display all the running processes in the FortiGate (the second column is the process ID’s) note the ones you want to restart. After some research, the fix (if rebooting is not an option) is to access the device using SSH, login as admin, then execute the following commands: Additionally the configuration had not changed nor had the device experienced any issues that required reloading the configuration. were still functional but the GUI did not respond when trying to open the management page to log in. Recently we experienced an issue with a FortiGate firewall where you could not access the GUI using the management IP address although it had been working without issues previously.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
March 2023
Categories |